Products Found: 216

Showing Results For: Safety IO Modules

Safety IO Modules


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Rohs Verified
R1.190.1640.0, Wieland
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 574.70
Rohs Verified
772170, Pilz
11 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 288.89
Rohs Verified
3SK1213-2AJ20, Siemens
97 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 307.27
Rohs Verified
3SK1211-1BB40, Siemens
5 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 156.29
Rohs Verified
3SK1211-2BB00, Siemens
57 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 210.99
Rohs Verified
3SK1211-2BB40, Siemens
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 156.29
Rohs Verified
3SK1213-1AJ20, Siemens
31 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 307.27
Rohs Verified
3SK1213-2AB40, Siemens
32 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 307.27
Rohs Verified
3SK1211-1BW20, Siemens
56 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 159.52
Rohs Verified
3SK1213-2AL20, Siemens
83 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 307.27
Rohs Verified
3SK1213-1AL20, Siemens
16 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 307.27
Rohs Verified
3SK1213-1AB40, Siemens
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 227.61
UE403-A0930, Sick
4 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 450.53
Rohs Verified
3SK1211-1BB00, Siemens
15 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 210.99
Rohs Verified
6ES73176FF040AB0, Siemens
28 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 7232.42
Rohs Verified
6ES73177UL100AB0, Siemens
29 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 9631.24
Rohs Verified
6ES73262BF410AB0, Siemens
32 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 1503.75
Rohs Verified
6ES71957KF000XA0, Siemens
25 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 257.07
Rohs Verified
6ES73172FK140AB0, Siemens
27 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 7923.69
Rohs Verified
6ES71946KB010AA0, Siemens
23 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 60.09
Rohs Verified
6ES73261RF010AB0, Siemens
31 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 1565.03
Rohs Verified
6ES71366CB000CA0, Siemens
22 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 753.88
Rohs Verified
6ES73934AA100AA0, Siemens
35 In Stock
Check Stock & Lead Times Packaging Options
5 +
£ 4.67
Rohs Verified
6ES73156FF040AB0, Siemens
26 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 3408.43
Rohs Verified
6ES73183FL010AB0, Siemens
30 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 9511.34
Showing
1 -

New Items
New items
SMS31, Carlo Gavazzi

SMS31, Carlo Gavazzi

The Carlo Gavazzi safety modules are designed in Category 4, performance Level e in accordance with the Machine Directive EN ISO 13849-1 to monitor and control safely the safety circuits in applications with emergency stops, safety gates, safety magnetic switches, safety limit switches and electromechanical interlocks. They are also used to control safely the safety circuits of the lift car levelling and the lift pit inspection, in compliance with the lifts standards EN81-20 and EN81-50. Multiple types inputs Machinery directive compliance. Cat. 4, PL e in accordance with EN ISO 13849-1 Lift directive compliance- EN81-20 and EN81-50 standards Multiple operating modes Electromechanical forcibly guided safety relays with 3NO+1NC Flexible wiring- Diagnostic- LED indications for power supply
New items
PDM-IOP-4CC-IOP, Schmersal

PDM-IOP-4CC-IOP, Schmersal

Input expander / PDM For parallel IO devices Passive distribution module for series-wiring Cage clamps For up to 4 safety switchgears Fuse protected device ports For installation in terminal boxes Protection class IP00
New items
PFB-IOP-4M12-IOP, Schmersal

PFB-IOP-4M12-IOP, Schmersal

Input expander / PFB For parallel IO devices Passive field box for series-wiring For devices with M12 Connector, 8-pole For up to 4 safety switchgears Fuse protected device ports Heavy duty version for field installation Protection class IP67
New items
3SK1211-1BB40, Siemens

3SK1211-1BB40, Siemens

SIRIUS 3SK1 Expansion Module The 3SK1 output expansion units are used to expand the enabling circuits. The maximum Performance Level PL / Cat. in accordance with ISO 13849-1, SILCL in accordance with IEC 62061, SIL in accordance with IEC 61508 corresponds to the Performance Level PL and SIL of the basic unit when the connection between basic unit and output expansion is configured as fail safe (e.g. basic unit and output expansion are connected using 3ZY12 device connector ). The output expansions can be activated via the supply voltage (A1/A2) or using 3ZY device connectors.The operating state of the 3SK1 output expansions is displayed on the LED. The output expansions 3SK1211(4RO) have four safety related enabling circuits as NO circuits, and the output expansions 3SK1213 (3RO) have three. They each have one positively driven NC circuit. The output expansions can be activated via any enabling circuit / output of the basic unit via (A1). The NC circuit 51/52 of 3SK1211 (4RO) or 41/42 of 3SK1213 (3RO) is used for monitoring the output expansions. In the 24 V DC variants, the expansion units can be activated and evaluated via the 3ZY device connectors.Output expansion 3SK1211 Slide switch for selecting the activation type (time delayed / instantaneous - for 24 Vdc variant only)1 LED for status display4 enabling circuits (safe circuits, NO contacts)1 NC circuit as feedback contact for output expansion 3SK1211 to the up-circuit basic unitEnclosure width 22.5 mmRemovable terminalsOutput expansion 3SK1213 Slide switch for selecting the activation type (time delayed / instantaneous - for 24 Vdc variant only)1 LED for status display3 enabling circuits (safe circuits, NO contacts)1 NC circuit as feedback contact for output expansion 3SK1213 for the up-circuit basic unitEnclosure width 90 mmRemovable terminalsNote ...
New items
772171, Pilz

772171, Pilz

PNOZmulti 2 Motion Monitoring Modules The PNOZ m EF *MM expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Two models are available: PNOZ m EF 1MM provides safe monitoring of one axis and PNOZ m EF 2MM provides safe monitoring of two independent axes. Features and Benefits Can be configured in the PNOZmulti Configurator Monitoring of 1 axis, stock no. 918-6617 Monitoring of two independent axes, stock no. 918-6611 Measured value recorded by proximity switch and encoder LED display for supply voltage, diagnostics, axis status and errors Support the safe drive function in accordance with EN 61800-5-2 Applications Safe speed monitoring (SSM) Safe speed range monitoring (SSRM) Safe direction of movement monitoring (SDIM) Safe operating stop monitoring (SOSM) Analogue voltage (track S) Standards EN ISO 13849-1 PLe; EN ISO 13849-1 Cat. 4; EN IEC 62061 SIL CL 3; IEC 61511 SIL 3. Approvals CE, cULus Listed, TÜV, BG, CCC. Supplied with Screw terminals. Safety Controller
New items
LG5925.48/61 AC/DC24V, Dold

LG5925.48/61 AC/DC24V, Dold

LG 5925 - Emergency stop module, LG 5929 - Expansion module Applications Emergency stop and expansion modules for - Machine emergency stop switching - Monitoring sliding grill guards General data Safety category 4 in accordance with EN954-1 Operating status indicator 22.5 mm overall width Emergency stop module LG 5925.48 1 or 2-channel configuration Line termination recognition on the ON button with or without crossover recognition Expansion module LG 5929.60 Use only with a higher-level emergency stop module Redundant and force guided contacts 1-channel configuration Input Emergency stop module Expansion module Nom. voltage: 230 VAC or 24 VAC / DC 230 VAC or 24 VAC / DC Control voltage: 22 VDC at S11 with U N - Control current: 25 mA with U N 75 mA Output Contact assignment: 3 N/O / 1 N/C 5 N/O / 1 N/C Therm. current I th : 5 A max. 5 A max. Switching capability according to AC 15: - N/O: 3 A / 230 VAC - N/O: 3 A / 230 VAC - N/C: 2 A / 230 VAC - N/C: 2 A / 230 VAC Mechanical lifespan: >20 x 10 6 switching cycles >20 x 10 6 switching cycles General data Rated operating current type: Continuous operation Continuous operation Mounting: DIN rail DIN rail Housing material: Thermoplast Thermoplast Protection class: - Housing: IP40 - Housing: IP40 - Terminals: IP20 - Terminals: IP20 Dimensions (H x W x D): 22.5 x 90 x 121 mm 22.5 x 90 x 121 mm Weight: 220 g 205 g Ambient temperature: -15 °C → +55 °C -15 °C → +55 °C Approvals CE Standards EN 60204-1 (stop functions), EN 418, prEN574, prEN 954-1, IEC / EN 60204-01, EN 954-1
New items
R1.190.1060.0, Wieland

R1.190.1060.0, Wieland

The Wieland samosPRO IO-module has 8 non-safe inputs, 4 non-safe outputs and 4 configurable nonsafe I/O. It has pluggable push-in terminals. Spring clamp type connection available Inputs and outputs are configurable It has short circuit protection
New items
6EP4436-8XB00-0DY0, Siemens

6EP4436-8XB00-0DY0, Siemens

The Siemens SITOP CNX8600 8x2.5 A expansion module output of 24 V DC or 8x 2.5 A outputs. Simultaneous connecting in of all outputs after device booting or delay time of 25 ms, 100 ms or load optimized for sequential cutting-in of the outputs via DIP switches at power supply unit can be set. 3-color LED for operating state module 3-color LED per output for operating state output Relay contact or changeover contact, contact current capacity DC 60 V and 0.3 A for Operating state OK at power supply unit PSU8600 Snaps onto DIN rail EN 60715 35x15 Suitability for interaction modular system Removable terminal at output Design of short-circuit protection- electronic overload cut-off
New items
772132, Pilz

772132, Pilz

PNOZmulti 2 Communication/Fieldbus Module Profibus The PNOZ m ES Profibus expansion module connects to a base unit from the PNOZmulti 2 configurable control system. Features and Benefits Can be configured in the PNOZmulti Configurator Connection for PROFIBUSDP Station addresses from 0 ... 99, selected via rotary switch Status indicators for communication with PROFIBUSDP and for errors In the PNOZmulti Configurator, 128 virtual outputs of the PNOZmulti 2 control system can be defined for communication with the fieldbus PROFIBUSDP Maximum 1 PNOZ m ES Profibus can be connected to the base unit Transmission rate: maximum 12 Mbps Connection to fieldbus via female 9-pin D-Sub connector Approvals CE, cULus Listed, TÜV, BG, CCC. Supplied with Screw terminals. Safety Controller
New items
2TLA010030R0000  E1T 0s 24DC, ABB

2TLA010030R0000 E1T 0s 24DC, ABB

E1T Safety Expansion Relay Series By using the E1T safety expansion relay from ABB it is easy to increase the number of safe outputs. This means that an unlimited number of dangerous machine operations and functions can be stopped from one safety relay. The E1T from ABB is a safety expansion relay series which incorporates twin stop functions Includes LED status indication 35 mm DIN rail mounting IP40 protection rated enclosure and IP20 rated connection blocks Impulse withstand voltage of 2.5kV Has four normally open outputs (4NO)
New items
UE410-XM3, Sick

UE410-XM3, Sick

UE410-MM3 Muting Main Unit and UE410-XM3 Muting Extension Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches 2 or 4 muting sensors 1 reset/restart input and external device monitoring Activation and time adjustable 0.33 to 60 min Type of output safety capable outputs: PNP semiconductors, short-circuit protected, cross-circuit monitored Maximum output current: 2A Maximum response time: 13 ms Maximum switch on time: 10 s Maximum power consumption: 3 W Category 4 (EN ISO 13849), SIL3 (IEC 61508), SILCL3 (IEC 62061), PL e (EN ISO 13849) Configurable Safety Relay
New items
UE410-XU3T5, Sick

UE410-XU3T5, Sick

UE410-XU Expansion Module, Input/Output The UE410-XU module is an input/output extension with 4 safety inputs, 4 semiconductor outputs and 2 test outputs. It has the same switch positions, logic functions and connection possibilities for sensors as the UE410-MU. In contrast to the UE410-MU, the UE410-XU cannot store the system configuration Note A UE410-MU and several UE410-XU units can be linked logically with each other, thus forming a subsystem Configurable Safety Relay
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Safety IO Modules and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Safety IO Modules or any other product.
This depends on the Safety IO Modules individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Safety IO Modules and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Safety IO Modules.
Yes. We keep updating our stock frequently and if a product like Safety IO Modules is not in stock then we will let you know.